Contactors: Motor Control, Lighting, HVAC,
Power, 3 or 4 pole. Efficient New
Streamline, Smaller, Low Power Drain, Low
Noise, Easy to Install.
931810
32 Amp. AC-1, 18 Amp. AC-3
Normally Open (N.O.)
contacts
600V
32A. Incandescent, LED or resistive load
20A. Ballast, Motor 7.5HP @480V
Auxiliary contact 1NO/1NC
Power Lug Terminal Capacity AWG # 6 Coil
110/120VAC
Details*
Specifications
933210
50
Amp. AC-1, 32 Amp. AC-3 Normally Open (N.O.)
contacts 600V 50A.
Incandescent, LED or resistive load 32A. Motor control, 20HP@
480VAC Auxiliary contact 1NO/1NC
Power Lug Terminal Capacity AWG # 4
Coil 110/120VAC Details*Specifications
933210
120VAC $39.99
.
934060
60
Amp. 4 Pole
(Silent Operation)
Normally
Open (N.O.) contacts
For
120/220/277/Rated 500V,
7.5HP @240V, 15HP @460V
40A. Ballast, 7 KW@ 220VAC
Dimension: 2.2w x 3.3h x 2.5d inch
60Amp AC-1, 32Amp AC-3
Power Lug Terminal Capacity AWG # 4 Coil 110/120VAC
add DIN rail
934006
60Amp.
4 Pole N/C (Silent Operation)
Normally closed (N.C.) contacts
For
120/220/277/Rated 400V, 60A. Incandescent or resistive load AC1 32A. Ballast and General purpose AC3
Power
indicator, DIN mount Dim: 2.2 x 3.5 x 2.5 in
(55 x 90 x 70 mm)
Power Lug Terminal Capacity AWG # 4 Specificationsadd DIN rail
100 Amp. 4 Pole
Slim contactor
Normally
Open (N.O.) contacts For 120/220/277/Rated
500V,
50A. Ballast, 10 KW@ 220VAC, 15KW@277V 100A AC-1, 40A. AC-3 40A, 24VDC, DC Switching Power
indicator, DIN mount
Dim: 110 x 81 x 68 mm)
Dimensions
Power Lug Terminal Capacity AWG # 2/0 120VAC coil
100 Amp. 4 Pole
Slim
contactor
Normally closed (N.C.) contacts
For 120/220/277/Rated
500V,
50A. Ballast, 10 KW@ 220VAC, 15KW@277V 100A AC-1, 40A. AC-3 40A, 24VDC, DC Switching Power
indicator, DIN mount
Dim: 110 x 81 x 68 mm)
Dimensions
Power Lug Terminal Capacity AWG # 2/0 120VAC coil
40 Amp. 4 Pole 944120 Normally Open
(N.O.) contacts NEMA Definite purpose
10HP @240V, 15KW 277VAC
40 A. Ballast, 7 KW@ 220VAC
50A AC-1, 40A. AC-3 600V
Lighting - Refrigeration - HVAC
Dim: 2.75 x 3.5 x 3.0 in (70 x 90 x
75 mm)
Power Lug Terminal Capacity AWG # 4
120VAC coil
SPECIFICATIONS
40 Amp.
3 Pole 943120 Normally Open
(N.O.) contacts NEMA 2 Definite purpose
10HP @240V, 15KW 277VAC
40 A. Ballast, 7 KW@ 220VAC
50A AC-1, 40A. AC-3 600V
Lighting - Refrigeration - HVAC
Dim: 2.75 x 3.5 x 3.0 in (70 x 90 x
75 mm)
Power Lug Terminal Capacity AWG # 4 120VAC coil
100 Amp. 3 Pole LS series
Normally
Open (N.O.) contacts
Rated 600V,
2 N/O, 2 N/C Auxiliary Contacts
20HP
@240V, 75HP @460V
Dimension: 3.3w x 5.3h x 4.1d inch 160Amp AC-1, 100Amp AC-3
Power Lug Terminal Capacity AWG #00 Coil Selection
120, 208, 230VAC add DIN rail
40
Amp. 3 Pole, LS series AC-1, 60Amp. AC-340Amp Normally Open (N.O.)
contacts 600V